Power Meter-Logger is a meter that is capable of not only measuring and displaying thirty-six electrical parameters but has the capability to log and store 1000 sets of five important parameters in internal memory. Facility to increase data logging facility for more than 1000 records is available on request. The recording interval is normally one hour but can be changed upon prior request. Any variation in load by more than 20 per cent is also recorded. The meter is provided with communication port and appropriate software for accessing recorded data. CT/PT ratio is programmable. Facility to calibrate voltage, current and Power factor of individual phase is provided through Keyboard and Display. Password is user-programmable.
The meter is available in two versions: with LCD and with Seven-segment LED display.
Measures True RMS with Data Logging.
Technical Specification:
Parameter
|
Specification
|
|
Input Supply
|
230 V +-10% AC, 50 Hz.
|
|
Three phase Voltage Input
|
Maximum 415 volts, Star
|
|
Fuse Rating
|
500 mA
|
|
Parameter Refreshing Time
|
500 ms
|
|
Parameter update time on GUI
|
2 seconds
|
|
CT Ratio
|
Programmable
|
|
Communication/Protocol
|
RS 232 or RS 485 MODBUS-RTU
|
|
Baud Rate
|
9600/19200 bps programmable
|
|
Accuracy, Of Full Scale
|
Active Energy, Instantaneous Power
|
0.5%
|
|
Frequency
|
0.5 %
|
|
LCD
|
16x2 alphanumeric backlit
|
|
Display
|
LED
|
4 digit, 7 segment, 0.5â€ÂÂx 2
|
|
For Logged Data
|
PC based GUI
|
|
Date and Time
|
|
|
Parameters Logged, 3 phase
|
Frequency
|
|
Equivalent Line Voltage
|
|
Equivalent Current
|
|
Equivalent Active Power
|
|
Cumulative Hours and Full Load
|
|
IP 5x, ABS Molded Plastic
|
|
Enclosure
|
L Type, 7+3 Pin detachable Phoenix
|
|
Termination Details
|
4 for LCD, 4 for LED
|
|
Membrane Keys
|
Flush on Panel-DIN Standard
|
|
Mounting
|
92 x 92 mm
|
|
Cutout
|
96 x 96 mm
|
|
Bezel
|
130 mm behind bezel with CT inside
|
|
Depth
|
670 grams
|
|
Weight
|
Five Parameters (Logging)
|
|
Calibration Setting in GUI
|
|
|
Environmental Conditions:
|
0-55 Degree Celsius
|
|
Operating Temperature
|
-25 to 70 Degree Celsius
|
|
Storage Temperature
|
0 to 95%, Non-condensing at 40 Deg.C.
|
|
|
|
Parameters Measured and Displayed:
|
Frequency (Hz)
|
Apparent Power Line 2
|
|
3 Phase Equivalent Voltage
|
Apparent Power Line 3
|
|
Line Voltage (L1-L2)
|
Maximum Equivalent Apparent Power
|
|
Line Voltage (L2-L3)
|
3 Phase Equivalent Active Power
|
|
Line Voltage (L1-L3)
|
Active Power Line 1
|
|
Phase Voltage (Vr)
|
Active Power Line 2
|
|
Phase Voltage (Vy)
|
Active Power Line 3
|
|
Phase Voltage (Vb)
|
Maximum Equivalent Active Power
|
|
3 Phase Equivalent Current
|
3 Phase Equivalent Reactive Power
|
|
Line Current (Iry)
|
Reactive Power Line 1
|
|
Line Current (Iyb)
|
Reactive Power Line 2
|
|
Line Current (Ibr)
|
Reactive Power Line 3
|
|
3 Phase Equivalent PF
|
3 Phase Equivalent Active Energy
|
|
Power Factor Line 1
|
Active Energy Line 1
|
|
Power Factor Line 2
|
Active Energy Line 2
|
|
Power Factor Line 3
|
Active Energy Line 3
|
|
3 Phase Equivalent Apparent Power
|
3 Phase Equivalent Apparent Energy
|
|
Apparent Power Line 1
|
3 Phase Equivalent Reactive Energy
|
Parameters recorded and displayed in GUI:
|
Cumulative Hours and Full Load
|
3 Phase Equivalent Line Voltage
|
|
Date and Time
|
3 Phase Equivalent Current
|
|
Frequency
|
3 Phase Equivalent Active Power
|
|
Number of Records-1000 sets
|
|
Special Features:
-
Measurement of 36 electrical parameters,
-
Recording of five critical parameters at predetermined interval,
-
Facility for uploading of data for system analysis and corrective actions,
-
Eminently suitable for captive power generation, supply of power to grid, and a host of applications.
Recorded data can be uploaded in PC or Laptop Computer through the communication port RS 232 or RS 485 MODBUS-RTU protocol. RS 232 cable is provided for retrieval of recorded data for RS 232 model only. Display and calibration of parameters such as Voltage (0-415 Volts without external PT and 0-440 KV with external PT), Current 0-5 A without external CT, Frequency, Date and Time can be done with PC based GUI. Parameters like Power Factor per phase and Instantaneous Power per phase are displayed in the GUI. Facility to nullify the residual data related to current per phase can also be done through GUI. The product is supplied with operating GUI
Precaution:
Only authorized persons should perform the Administration mode and Residual mode of operation to ensure integrity of entered data.
www.powerenergyconservation.com &
|